Technical specifications

Data for all 13 HAW lining materials and both repair systems, from HAW's technical data sheets.

Compound Data

13 linings, by base material and temperature

Every HAW lining is selected and compounded for the customer's specific chemical environment. The base material and maximum service temperature below narrow the field — for a resistance rating against your exact chemical, concentration, and operating temperature, send us the details and we'll confirm the right compound.

Soft rubbers

7 products
CodeBaseTempResistant toSheet
HAW-W01CIIR≤ 100 °Chydrofluoric acidPDF
HAW-W03CR≤ 80 °Cacid at lower concentrations · lye, brinesPDF
HAW-W06BIIR≤ 100 °Calkaline and acids · oxidizing agents at lower and medium concentrations +1PDF
HAW-W06LBIIR≤ 100 °Calkaline and acids · oxidizing agents at lower and medium concentrations +1PDF
HAW-W08BIIR≤ 125 °Cnitric acid (up to 30%) · acid mixtures +1PDF
HAW-W12CSM≤ 80 °Calkaline and acidic media · oxidizing acids (with exceptions)PDF
HAW-W31IR/SBR-45 to 100 °Calkaline and acidic at medium concentrationsPDF

Hard rubbers

5 products
CodeBaseTempResistant toSheet
HAW-H05IR≤ 80 °Calkaline and acid fluids with the exceptions of oxidizing fluids · aliphatic hydrocarbons (with exceptions) and alcoholPDF
HAW-H22IR≤ 130 °Calkaline and acid fluids with parts of organic solventsPDF
HAW-H22RIR≤ 125 °Calkaline and acid fluids with the exception of oxidizing fluidsPDF
HAW-H90IR≤ 100 °Calkaline and acid fluids with the exceptions of oxidizing fluids · aliphatic hydrocarbons (with exceptions) and alcoholPDF
HAW-H94IR/SBR≤ 100 °Calkaline and acid fluids with the exceptions of oxidizing fluidsPDF

Resin lining and repair systems

3 products
CodeBaseTempResistant toSheet
BOHA 6101PH0 to 120 °COnly resistant to alkalines ph < 9 · good resistance to acids (exceptions: oxidizing acids) +1PDF
HAW-C16EP-15 to 80 °Canorganic acids · non oxidisuíng acids +2PDF
HAW-C21PH/RES-15 to 120 °Canorganic acids · organic solvents +1PDF

See how these compounds are applied on the Rubber Linings page.

Vulcanisation Capacity

Europe's largest autoclave

Autoclave dimensions and cure conditions available at the Bockenem facility.

6,000
mm
Max diameter
20,000
mm
Max length
150
°C
Cure temperature

Have a project to discuss?

Send us the scope, a drawing or a specification. Our engineers come back with a solution, a price and a programme.